Kiw Re-Acetoning Machine Cylinder Management System
Flexible System adapted to Production reporting as per each site – No Manual Calculation – Easy to Operate
PR 1713 Series of controllers with characteristics like 35,000 hrs. MTBF, extensive data storage facility, Flash Memory leads to
calibration data being stored without any fear.
The stainless steel enclosure and emergency data entry from build in keyboard makes life easier also these controllers can be programmed by any engineer who knows PLC programming In IEC – 6 1131
Residual gas calculation and acetone filling an all new re-acetoning machine able to handle the addition of acetone into acetylene cylinders in a reliable, accurate and fast manner.
The KIW Re-Acetoning machine consists of a weighing platform, a local operator interface ( incorporating a message screen and keypad ) and an acetone connection in combination with temperature and pressure measurement capability
A pneumatically operated control valve doses acetone into the acetylene cylinders. All production information is collected and analysed remotely by KIW’s exclusive. FILL RIGHT KONTROL software which operates in a PC/AT environment.
OVERVIEW:
- Highly accurate batching of acetone into all types of acetylene cylinders
- Precise calculation residual gas and acetone loss using our exclusive KIW FILL-RIGHT software (international patent pending).
- User friendly operators are interface for quick and easy operation.
- No more manual data recording.
- No more reference to pressure tables.
- Database of all cylinders grouped according to type, size volume of each cylinder.
- Additional remote diagnostics and cylinder barcoding options available.
- Re-acetoning machine available on stationary or mobile versions.
Weighing platform capacity 0-150 Kg
Scale Range Two ranges of 0-60 kg and 0-150 Kg
Weighing Accuracy +/- 0.003 % of the selected ranges
Cylinder size range Max diameter: 310 mm
Height range 500-1200 mm
Pressure Measurement Range 0-30 bar
Pressure Measurement Accuracy +/- 5 KPa
Temperature Measurement Accuracy +/- 0.50 C ( +/- 10 F )
Acetone Addition Accuracy +/- 0.02 kg
Keyboard Display LCD; 2 x 20 characters; 12.7 mm
Keys 8; 15 x 15 mm
Power Requirement 240 V, 50 Hz
Air Supply Dry, Filtered oil free, compressed air in a non-hazardous location. Minimum 450 Kpa ( gauge), Maximum 800 KPa ( gauge), 100 normal litres per minute nominal Electrical Classification Class 1 Zone 1 Gass Group IIC, T3, acetylene hazardous area, classified in accordance with AS 2430.1-1987 Environment & Location 0-450 C max, ambient, indoor Material: Frame: Mild steel, powder coated pipework & fittings